The 4100-HCF provides continuous monitoring of separated oil thickness on a water surface. It monitors a floating sensor on the water surface to indicate the thickness of separated oil. An LCD display of the thickness, analog output and relay alarms are standard.
The 4100-HCF float sensor monitors the capacitance field of the water surface. As the oil accumulates on the surface, the sensor capacitance changes. This interface signal is used to provide outputs, displays and relay control.
Operating Temp. 0˚C to +55˚C
Resolution .007% (.07 pF at 1,000 pF)
Accuracy .04% of full scale pF
Power Input 24 vdc or 80-240 vac +/-10%, 1P, 50-60 HZ
Display touch screen full colour sump view graphics,
% and engineering units of oil
selectable trend line view or none
Relay Outputs four SPDT, 10 amp @ 240 vac, dry Pump relay has a discrete run time with level re-set
Enclosure Type 4 metal painted blue / IP 66
optional Type 4X SS or polycarbonate
Approvals to UL / CSA / CE
IEC 61010
Style #A00761 0 to 25 mm (0-2”) oil thickness range
Style #A00765 0 to 300mm (0-12”) oil thickness range
Process Temp. 0˚C to +55˚C
Ambient Temp. -60˚C to +55˚C
Intrinsic Safety Approved Intrinsically Safe when ordered with Approved Barrier in Control Unit
CAN/CSA E60079-11:
Class I, Groups A,B,C,D;
Class II, Groups E,F,G;
Class III, Encl.Type 4
CRN ABSA-CRN #OF07450.2
Wetted Parts 304SS, PVC and Teflon
Optional probe materials are eligible for NACE MR-0175 Compliance
Semrad Pty Ltd is a leading Australian distributor of level switches and level transmitters, designed specifically for harsh industrial applications, including caustic and chemical solutions.
Semrad is dedicated to providing customers with the most cost effective and technically advanced solutions for the measurement and control of liquid and bulksolids level.
© 2020 Semrad Pty Ltd All Rights Reserved. Privacy Policy | Sitemap |