Suitable for liquid and gas applications
Non-invasive clamp-on flow measurement
High measurement accuracy
Quick and easy installation
No pressure loss
Hygienic and contamination-free measurement
Low maintenance and operating costs
Approved options for hazardous areas
High-temperature capability up to 380°C
Integrated heat energy measurement

The fixed clamp-on ultrasonic flowmeter DeltawaveC-F is designed for permanent installation and offers similar functionality to the portable clamp-on flowmeter DeltawaveC. The new, universally applicable clamp-on ultrasonic flowmeter for liquid media in filled pipes works according to the highly accurate ultrasonic time-of-flight method.
The ultrasonic transducers are strapped onto the pipe from the outside (clamp-on or buckle-on technology). It is not necessary to cut the pipe, there are no pressure losses. Because the transducers are not in contact with the medium, the measurement is 100% contamination-free and thus 100% hygienic. This is particularly beneficial for quantity measurements of food and pharmaceutical products. And if you have to measure particularly toxic or environmentally harmful liquids, there are no additional sealing surfaces or dead volumes when measuring flow with deltawaveC.
With the DeltawaveC-F, the drinking water flow is measured according to the ultrasonic time-of-flight method via clamp-on transducers. This enables precise and very dynamic flow measurement, especially as the measurement process takes place many times, usually 50 to 150 times per second. Thus, in combination with the extremely accurate signal evaluation, measurement results can be determined very reliably and practically drift-free even in fast-flowing liquids. In doing so, the clamp-on ultrasonic flow meter DeltawaveC-F meets or exceeds even the highest requirements for precise flow measurement.
Strict hygiene standards apply to drinking water measurement – and rightly so, because there must be no contamination here. The clamp-on flowmeter DeltawaveC-F is the ideal tool because it masters non-contact flow measurement. The measuring sensors do not come into contact with the drinking water at any time. This eliminates the risk of contamination from the outset. This makes drinking water measurement with the DeltawaveC-F 100 percent hygienic.

DeltawaveC-F is very easy to handle. The user interface of the large graphical display is easy to master even without training. Installation and parameterisation of the DeltawaveC-Fix only take a few minutes. It is not necessary to cut the pipeline; it is sufficient to strap the ultrasonic transducers onto the respective pipeline from the outside (clamp-on). A Quickfix mounting set is included in the scope of delivery for smooth installation. With the help of the Quick-Setup option, all necessary parameters can be set in a few minutes.

Both the transmitter and the DeltawaveC sensors are Ex d (pressurised enclosure) approved. You do not have to do without the large display and the familiar simple operating concept of the transmitter. With clamp-on flow meter deltawaveC, you can combine Ex and non-Ex transducers according to your requirements: If, for example, only a small radius around the pipeline is Ex-area, you can place the transmitter without Ex outside the Ex-area and order only the ultrasonic transducers in Ex-design. This saves costs and does not compromise safety.
The clamp-on measurement of gases is a particularly demanding measurement task, which DeltawaveC-F solves optimally with its new Auto-Optimiser. The advantages include no intervention in the pipeline (DN25-DN700), retrofitting, no wear or pressure loss and no sealing surfaces. The technology is particularly suitable for compressed air, natural gas pipelines, in air separation plants and large refrigeration plants. The newly developed Lamb Wave transducers cover pipelines with wall thicknesses from 1 to over 20 mm and diameters from 25 to 700 mm.
The new, directly-applied high-temperature converters withstand temperatures up to 380°C. And because the converters do not require spacer plates (hockey sticks), installation of the clamp-on ultrasonic flow measurement is much easier and the signals are significantly more stable and better than with conventional high-temperature converters.
This means you can now use DeltawaveC on mediums such as tar, thermal oil, boiler feed water and various hydrocarbons in the refinery.
Due to the clamp-on technology, your DeltawaveC-F operates:
This makes your DeltawaveC-F a long-term stable and reliable measuring device for the vast majority of liquid applications.
The DeltawaveC-F measures according to the highly accurate ultrasonic time-of-flight method. With this method, the flow is measured many times, typically 50-150 times, per second. Due to the high number of measurements, but also because of the use of state-of-the-art digital signal evaluation, DeltawaveC works drift-free and reliably. Even with demanding measurements and media with gas and particle loads.
Already integrated as standard with deltawaveC-F is heat quantity measurement. In addition to precise flow measurement, the DeltawaveC-F also reliably and accurately records the heat output and heat quantity.
Regarding the sensors, you can choose the precise and easy-to-install contact temperature sensors from Systec Controls or you can also use PT100 temperature sensors for flow and return temperature that are available on site. With a temperature resistance of -40 to 150°C, DeltawaveC-F covers the vast majority of applications in heating and cooling circuits.
Contact us to discuss the fixed clamp-on flow meter and find the right solution for your application.