Fixed Clamp-on Ultrasonic Flow Meter and Heat Meter DeltawaveC-F

Features

  • Suitable for liquid and gas applications

  • Non-invasive clamp-on flow measurement

  • High measurement accuracy

  • Quick and easy installation

  • No pressure loss

  • Hygienic and contamination-free measurement

  • Low maintenance and operating costs

  • Approved options for hazardous areas

  • High-temperature capability up to 380°C

  • Integrated heat energy measurement

Product Enquiry Form (#1)

Product Description

Clamp-on Ultrasonic Flow Meter DeltawaveC-F

clamp-on heat meter

The fixed clamp-on ultrasonic flowmeter DeltawaveC-F is designed for permanent installation and offers similar functionality to the portable clamp-on flowmeter DeltawaveC. The new, universally applicable clamp-on ultrasonic flowmeter for liquid media in filled pipes works according to the highly accurate ultrasonic time-of-flight method.

The ultrasonic transducers are strapped onto the pipe from the outside (clamp-on or buckle-on technology). It is not necessary to cut the pipe, there are no pressure losses. Because the transducers are not in contact with the medium, the measurement is 100% contamination-free and thus 100% hygienic. This is particularly beneficial for quantity measurements of food and pharmaceutical products. And if you have to measure particularly toxic or environmentally harmful liquids, there are no additional sealing surfaces or dead volumes when measuring flow with deltawaveC.

High Measuring Precision with Liquid Flow Meter DeltawaveC-F

With the DeltawaveC-F, the drinking water flow is measured according to the ultrasonic time-of-flight method via clamp-on transducers. This enables precise and very dynamic flow measurement, especially as the measurement process takes place many times, usually 50 to 150 times per second. Thus, in combination with the extremely accurate signal evaluation, measurement results can be determined very reliably and practically drift-free even in fast-flowing liquids. In doing so, the clamp-on ultrasonic flow meter DeltawaveC-F meets or exceeds even the highest requirements for precise flow measurement.

Hygienic Ultrasonic Flow Meter

Strict hygiene standards apply to drinking water measurement – and rightly so, because there must be no contamination here. The clamp-on flowmeter DeltawaveC-F is the ideal tool  because it masters non-contact flow measurement. The measuring sensors do not come into contact with the drinking water at any time. This eliminates the risk of contamination from the outset. This makes drinking water measurement with the DeltawaveC-F 100 percent hygienic.

flow meter for hydro carbon industry

Clamp-On Ultrasonic Flow Meter: Quick and Easy to Install and Set Up

Parameterisation in a very short time

DeltawaveC-F is very easy to handle. The user interface of the large graphical display is easy to master even without training. Installation and parameterisation of the DeltawaveC-Fix only take a few minutes. It is not necessary to cut the pipeline; it is sufficient to strap the ultrasonic transducers onto the respective pipeline from the outside (clamp-on). A Quickfix mounting set is included in the scope of delivery for smooth installation. With the help of the Quick-Setup option, all necessary parameters can be set in a few minutes.

liquid flowmeter deltawaveC now also in the Ex area

Clamp-On Flow Meter DeltawaveC-F is Approved for use in Hazardous Areas

Both the transmitter and the DeltawaveC sensors are Ex d (pressurised enclosure) approved. You do not have to do without the large display and the familiar simple operating concept of the transmitter. With clamp-on flow meter deltawaveC, you can combine Ex and non-Ex transducers according to your requirements: If, for example, only a small radius around the pipeline is Ex-area, you can place the transmitter without Ex outside the Ex-area and order only the ultrasonic transducers in Ex-design. This saves costs and does not compromise safety.

 

DeltawaveC-F Ultrasonic Flow Meter also Measures Gases

The clamp-on measurement of gases is a particularly demanding measurement task, which DeltawaveC-F solves optimally with its new Auto-Optimiser. The advantages include no intervention in the pipeline (DN25-DN700), retrofitting, no wear or pressure loss and no sealing surfaces. The technology is particularly suitable for compressed air, natural gas pipelines, in air separation plants and large refrigeration plants. The newly developed Lamb Wave transducers cover pipelines with wall thicknesses from 1 to over 20 mm and diameters from 25 to 700 mm.

High temperature converter up to 380°C for the clamp-on Ultrasonic Flow Meter

The new, directly-applied high-temperature converters withstand temperatures up to 380°C. And because the converters do not require spacer plates (hockey sticks), installation of the clamp-on ultrasonic flow measurement is much easier and the signals are significantly more stable and better than with conventional high-temperature converters.

This means you can now use DeltawaveC on mediums such as tar, thermal oil, boiler feed water and various hydrocarbons in the refinery.

 

Saves Installation and Operating Costs

Due to the clamp-on technology, your DeltawaveC-F operates:

  • 100% contact-free
  • 100% maintenance-free
  • 100% leakage-proof
  • 100% hygienically flawless
  • 100% pressure loss-free

This makes your DeltawaveC-F a long-term stable and reliable measuring device for the vast majority of liquid applications.

High Measuring Accuracy – Drift-Free and Robust

The DeltawaveC-F measures according to the highly accurate ultrasonic time-of-flight method. With this method, the flow is measured many times, typically 50-150 times, per second. Due to the high number of measurements, but also because of the use of state-of-the-art digital signal evaluation, DeltawaveC works drift-free and reliably. Even with demanding measurements and media with gas and particle loads.

Usable as a Clamp-On Heat Meter

Already integrated as standard with deltawaveC-F is heat quantity measurement. In addition to precise flow measurement, the DeltawaveC-F also reliably and accurately records the heat output and heat quantity.
Regarding the sensors, you can choose the precise and easy-to-install contact temperature sensors from Systec Controls or you can also use PT100 temperature sensors for flow and return temperature that are available on site. With a temperature resistance of -40 to 150°C, DeltawaveC-F covers the vast majority of applications in heating and cooling circuits.

Typical Applications of the Clamp-on-Ultrasonic Flow Meter:

  • Power plants
  • Main and secondary cooling water
  • District heating
  • Pump protection / commissioning
  • Water and wastewater management
  • Sewage plant inlet and outlet
  • Drinking water networks, inspection of water meters
  • Pump protection
  • Distribution and consumption measurements
  • Leakage detection
  • Building services
  • Hot and cold water
  • Cooling systems and air conditioning
  • Energy optimisation
  • Pump control and adjustment
  • Optimisation of the heating systems
  • Chemistry and petrochemicals
  • Crude and light oil
  • Industrial water and waste water
  • Aggressive and toxic media
  • Measurement of heat transfer media such as thermal oils
  • Food and drink industry
  • Hygienic measurement of the media
  • Heat quantity measurement in the energy supply

 

Contact us to discuss the fixed clamp-on flow meter and find the right solution for your application.