Suitable for water and wastewater measurement in pipes, open channels and rivers
Available in 2-, 4- and 8-path configurations
High measurement accuracy of up to ±0.5% of reading in filled pipes and channels
Continuous, reliable flow measurement under demanding conditions
Maintenance-free operation with virtually no pressure loss
Retrofitting possible without interrupting operations
Low power consumption, suitable for solar-powered applications
Advanced signal analysis for accurate measurement in challenging conditions
Integrated data logging with removable SD card
USB, Modbus and M-Bus communication interfaces
The ultrasonic flow meter for water and wastewater, DeltawaveVER2, is a multi-path flow measurement system designed for demanding applications where accuracy, redundancy and reliability are essential. With its hardware version – 2-, 4- and 8-paths – DeltawaveVER2 can now also be used for cost-effective applications with the highest demands.
DeltawaveVER2 is an ultrasonic flow metering system for water and wastewater in a wide range of applications, for example in filled pipes, partially filled pipes, open channels and rivers. The multi-path flow meter system permanently monitors itself and works even under extreme conditions maintenance- and calibration-free and extremely reliable. For district heating applications with highest demands there are especially high temperature transducers.
DeltawaveVER2 can be optimally used in the water and wastewater industry, in sewage treatment plants in industry and municipal utilities, in thermal power plants, in penstock and low head river hydro power plants.
The DeltawaveVER2 brings a lot of benefits that make its use even easier, more accurate and cheaper as the predecessor and most competitors:
The use of deltawaveVER2 offers many advantages:
When it comes to the precision and process capability of our products, we make no compromises. Our ultrasonic transducers withstand pressures far exceeding 100 bar and deliver stronger, more accurate signals than competitive products. Because ultrasonic signals can be disturbed by numerous influencing factors, Systec Controls has developed an innovative signal analysis strategy for DeltawaveVER2, which finds the ultrasonic signals even if the amplitude of the noise is a multiple of the signal amplitude. Through these intelligent evaluation strategies, we analyse each individual acoustic signal for quality and plausibility. We can therefore rule out incorrect measurements. Our multi-frequency / multi-signal method finds the optimum ultrasonic signal even under unfavorable conditions such as high gas and particle load of the fluid. In the vast majority of cases, we can also safely operate ultrasonic transducers from third-party suppliers.
The result is accurate, reliable and stable measurement data even under extremely unfavorable conditions. The deltawave electronics measure the transit time difference between the ultrasonic signals traveling with and against the flow direction with incredible precision, even at very low flow velocities. Several paths lead to the goal: The determination of the flow velocity is based on the ultrasonic transit time method: Two ultrasonic transducers emit sound waves into the medium at an angle α (15 – 75 °).
Deltawave supports cross-over measurement, where two acoustic paths are installed at each measurement level and their measured speed values ​​are averaged. The high measuring accuracy of Deltawave was, among others, determined, verified and confirmed by the Research Institute for Environmental Technology and Hydraulic Engineering (VPUW) at the University of Kassel.

Because of the high accuracy, field acceptance tests of hydraulic turbines, storage pumps and pump-turbines are possible due to ISO60041 and ASME PTC 18. Accuracies up to 1 % could be achieved in open channels without calibration.
In filled pipes or channels you will get an accuracy of 0.5 % of reading. But there is more to measuring with Deltawave than just accuracy. The optimised transducers ensure long-term stable measuring without maintenance.
Ultrasonic signals are disturbed by a large number of influences: EMC, gas or solid loading, machine noise etc. Systec Controls has developed a new kind of evaluation method to ensure an accurate and reliable measurement even under extreme conditions. Because of the signal correlation analysis the ultrasonic signals are cognizable even if the amplitude of the noise is a multiple of the signal amplitude. That and the high time-resolution of the transducers are the reasons that Deltawave measures even the smallest flow speeds reliably and
accurately.

The ultrasonic transducers of deltawave are simply mounted directly on the channel wall or pipe.
We develop and produce individual mounting solutions for your individual application. Uninterruptible mounting and servicing is possible for the very most applications. Using established mounting rails, as shown in the picture, is only one solution.

Because of its capability to serve up to 4 independent measuring points, Deltawave is an efficient and sophisticated ultrasonic flow measurement system. Using our individual mounting solutions, the installation and the set-up can be done very fast and economically. That and the maintenance-free operation ensure minimal operational costs.
It is possible to upgrade your Deltawave with additional transducers, for example to add a new measurement location, so Deltawave is ready for your future growth. This is another advantage to reduce your operational costs.
Please contact us for more information or to discuss your application.