Suitable for gas mass flow measurement, including compressed air
Measures gas mass flow, pressure and temperature in one device
Performs up to 2,000 measurements per second
Differential pressure measurement with pressure and temperature compensation
Suitable for pulsating flows and rapidly changing flow conditions
Virtually maintenance-free with low measurement drift
Highly resistant to contamination, oil films and condensate
Suitable for a wide range of flow rates, temperatures and pressures
Available as an insertion probe or screw-in Venturi for different pipe diameters
Standard 4–20 mA and 0–10 V DC analogue outputs, with optional pulse, CAN bus and Modbus communication
The DeltaflowC2 from Systec Controls is a gas mass flow meter that operates using the advanced differential pressure (DP) measurement principle to measure gas mass flow. This compact device is designed for fast, precise, real-time differential pressure measurement of gas mass flow. The flow meter combines highly sensitive differential pressure, static pressure and temperature sensors with a powerful processor, all within an exceptionally compact design.
The DeltaflowC2 performs up to 2,000 measurements per second, enabling rapid processing and filtering of differential pressure (DP), absolute pressure (Pabs) and temperature (T). This provides users with accurate gas mass flow signals, along with simultaneous pressure and temperature measurements. The DeltaflowC2 differential pressure flow meter is therefore suitable not only for steady flow measurement but also for applications involving rapidly changing flow conditions and pulsations, such as those found in compressors and combustion engines.
The DeltaflowC2 provides gas mass flow measurement while simultaneously monitoring process temperature and pressure, all within a single device. It is specifically designed for measuring and controlling airflow in ventilation systems, as well as other gases in pipes and ducts. The DeltaflowC2 is well suited to differential pressure flow measurement applications, including compressed air metering and gas mass flow measurement.
The DeltaflowC2 differential pressure flow meter is available in two models: an insertion probe for pipes with an internal diameter starting from 28 mm (1 inch) and a screw-in Venturi for smaller pipes with diameters ranging from ¾ to 1½ inches. Installation is straightforward, with the probe version requiring only a connection fitting on the pipe, while the Venturi version can be screwed directly into a pipe section.
The DeltaflowC2 features analogue outputs (4–20 mA and 0–10 V DC), a pulse output, CAN bus and Modbus RTU, allowing integration into a wide range of electrical and control systems. The analogue outputs can transmit not only gas mass flow measurements but also differential pressure (DP), temperature or absolute pressure (Pabs) signals.
Compared with a thermal mass flow meter, the DeltaflowC2 differential pressure flow meter offers several advantages. It compensates for the effects of pressure and temperature on flow measurement, providing compensated gas mass flow readings. Thermal mass flow meters and other gas mass flow meters can be sensitive to surface contamination from oil films, condensate and particles. The DeltaflowC2, on the other hand, is significantly less sensitive to these contaminants.
The DeltaflowC2 is virtually maintenance-free, offers low measurement drift and is suitable for a wide range of flow rates, temperatures, pressures and gases, including compressed air. Furthermore, the DeltaflowC2 can be installed in almost all pipelines and ducts using a single standard installation length, simplifying stock management and improving availability.
Unlike thermal mass flow meters, the DeltaflowC2 differential pressure flow meter can be adapted to different gases without recalibration. The gas mass flow measurement can be recalculated for different gases using the physical principles outlined in ISO 5167.

The DeltaflowC2 differential pressure flow meter is suitable for a wide range of industrial applications, including:
The DeltaflowC2 differential pressure flow meter is designed for straightforward on-site parameterisation, even for applications involving high flow rates and temperatures.
Users can define process parameters using the free Excel design tool and then enter three specific parameters directly into the DeltaflowC2 display, making setup quick and simple.
The DeltaflowC2 is highly resistant to contamination and oil films, requires minimal maintenance and offers low measurement drift. It is also suitable for a wide range of flow rates, temperatures and pressures.
The DeltaflowC2Â flow meter offers a versatile solution with standardised installation lengths suitable for a wide range of pipelines and ducts.
It features a simple, standardised design, making it a practical and convenient solution for a wide range of industrial applications.