Non-submersible pressure sensor / hydro-static bubbler
The WaterLOG® H-3531 FlashLite™ is a NIST traceable pressure sensor. The sensor directly measures dry gas with accuracy better than 0.02% FSO. Combining high accuracy and low cost, the H-3531 FlashLite™ is the clear choice.
Features
- Directly measure dry air gas pressure
- Pressure accuracy is 0.02% full scale
- Accuracy over temperature range exceeds ±0.02ft. (6mm) of water
- Built-in temperature compensation
- Operating temperature range -40 to +60C
- Easy to use Simple RS-232 Menu Interface
- SDI-12 output provides measurement data in engineering units such as feet or meters
- Standard mode: Quadrature, 0-5V, and RS-232
- Industrial mode: 4-20mA and RS-485 Interface for Modbus/H-355 Gas Purge System Control
- Easy to use with H-355 Gas Purge System
- Compatible with RS-232 Data Logger
- Enclosure is nonconductive and corrosion proof
- Low current operation (Less than 1mA standby)
- Extended SDI-12 command for setting the Stage to the current water elevation or pressure
- Programmable continuous update outputs Measure Rate mode
Specifications
| Accuracy |
(Maximum percent of error in measurement)
|
| Pressure: |
Less than or equal to 0.02% of full scale
output (FSO) over temperature range
referenced to a straight line stretched from
zero PSI to maximum pressure
|
| Temperature: |
Internal temperature ±1° C over
temperature range |
|
Resolution
|
(Smallest change detectable in output signal)
|
Pressure:
|
1 part in 1,000,000 (0.0001%) |
| Temperature: |
1 part in 1,000,000 (0.0001%) |
|
Linearity
|
Less than 0.02% deviation from a straight line referenced to
end points
|
Pressure Hysteresis
|
Less than 0.01% of FSO
|
Long-term Stability
|
Accuracy drift is less than ±0.05% of FSO per year
|
| Standard Pressure Ranges |
| Pressure |
Depth |
Accuracy |
0 to 15 PSI
|
0 to 34.6 ft. |
±0.007 ft. |
| 0 to 30 PSI |
0 to 69.20 ft |
±0.014 ft |
|
| Pressure Overload |
| Less than 2 times the rated pressure |
Download full specifications in PDF:
Waterlog specifications (10 kb)
Download PDF brochure:
Download Waterlog brochure (2210 kb)
|
WaterLOG Flashlite
Features
- Directly measure dry air gas pressure
- Pressure accuracy is 0.02% full scale
- Accuracy over temperature range exceeds ±0.02ft. (6mm) of water
- Built-in temperature compensation
- Operating temperature range -40 to +60C
- Easy to use Simple RS-232 Menu Interface
- SDI-12 output provides measurement data in engineering units such as feet or meters
- Standard mode: Quadrature, 0-5V, and RS-232
- Industrial mode: 4-20mA and RS-485 Interface for Modbus/H-355 Gas Purge System Control
- Easy to use with H-355 Gas Purge System
- Compatible with RS-232 Data Logger
- Enclosure is nonconductive and corrosion proof
- Low current operation (Less than 1mA standby)
- Extended SDI-12 command for setting the Stage to the current water elevation or pressure