General
Level switches based on the conductive principle may be applied to liquids having higher conductivity than 2 x 10-5 S/cm.
Probes with length corresponding to required switching levels are immersed in the liquid, which changes conductivity between the probes and either the tank wall or, for multiple probe models, a reference probe. This change in conductivity is sensed and converted into an output signal by the electronics.
Up to four probes plus a reference probe can be used depending on model.
Specifications
| Single probe sockets |
KSP-201 |
KSS-201 |
KSN-201 |
number of probe rods |
1 |
Probe socket material |
PP |
carbon steel BS 970220 |
316 stainless |
| Insulation |
PP |
PFA |
| Temperature |
-20°C to 100°C |
-20°C to 200°C |
| Pressure |
max. 0.3 MPa |
max. 1.6 MPa |
Process connection |
BSP 3/8" |
Electrical connection |
M6, with rubber cap |
| Enclosure |
IP20 |
| Weight |
0.1 kg |
Multi-probe sockets |
KSH-202 |
KSH-203 |
KSH-204 |
number of probe rods |
2 + reference |
3 + reference |
4 + reference |
Probe socket material |
316 stainless |
| Housing |
Cast Aluminium |
| Insulation |
PFA |
| Temperature |
-20°C to 200°C |
| Pressure |
max. 1.6 MPa |
Process connection |
BSP 1 1/2" |
Electrical connection |
1xPg 16 with protective Alu-cast |
| Enclosure |
IP65 |
| Weight |
0.4 kg |
| |
Submersible Probes |
Compact Probes |
| KSK-101 |
KKH-102 * |
number of probe rods |
- |
up to 4 insulated + reference probe |
Probe socket material |
316 stainless |
| Insulation |
- |
PFA |
| Housing |
PVC |
Alu-cast |
| Temperature |
-20°C to 80°C |
liquid: -15°C to 120°C
ambient: -15°C to 80°C |
| Pressure |
max. 0.6 MPa |
max. 1.6 MPa |
Process connection |
- |
BSP 1 1/2" 316 Stainless |
Electrical connection |
1xPg 9 |
2xPg 16 for 8-15mm cables
0.75-2.5mm2 wire cross section |
| Electrical protection |
- |
Class 1. |
| Mechanical protection |
- |
IP65 |
| Weight |
0.04 kg |
0.6 kg (without probe stems) |
* See Relay Units table for electrical specs for KKH-102
| Relay Units |
KRK-201 KRS-201 |
KRK-202 KRS-202 |
KKH-102 internal |
| Power Supply |
24/110/230 VAC 50/60Hz, +/- 10% |
24/110/230 VAC 50/60Hz, +10%/-15% |
| Consumption |
< 4 VA |
< 5 VA |
| Probe voltage |
18 V AC |
24 V AC |
| Probe Current |
0.3 - 1 mA |
max 0.08 mA |
| Output |
1x SPDT 250VAC 8A, AC12 |
2x SPDT 250VAC 8A, AC12 |
| Sensitivity |
fixed, max 50k |
Adj, 35 - 50k |
Adj, 35 - 50k |
| Time Delay |
0.3 - 1 mA |
0.3 - 1 mA |
- |
| Ambient temp |
-10°C - 55°C |
-15°C - 80°C |
| Enclosure |
IP40 KRK DIN rail, KRS 11 pin plug |
IP65 |
| Weight |
0.2 kg |
0.6 kg |
Accessories
KLN-2xx Probe Stem
xx = rod length, 01 (100mm) to 30 (3m)
Stainless steel probe rod is screwed into the socket by M6 thread. Rod length is according to switch point level.
KLP-104 Separator
A separator is recommended for use with probes >0.5m in length to ensure the spacing between electrodes is maintained. Made of PVDF.
Download PDF brochure (1174kb)
|
NivoCONT K series
conductive level switches
Features
- Low cost
- Limit switch or differential switch versions
- High or low fail-safe mode
- All wetted parts stainless steel
- Compact unit with two independent relays
- Separate probe and relay unit
Applications
- Conductive liquids with at least 2x10-5 S/cm conductivity
- Fail-safe indication
- Pump control
- Chemical and water industry
Specifications
| |
Power supply:
|
24,110,230VAC 50/60Hz
|
| |
Temperature:
|
-20°C to +200°C
|
| |
Pressure:
|
max. 16 bar
|
| |
Process connection:
|
3/8", 1 1/2"
|
| |
Protection:
|