Other related sites


The Next Generation compact ultrasonic liquid level transmitters.
Click here for more information
|
Fibreflex
Continuous Nuclear
Level Detector.
General
The FiberFlexª is a different type of scintillation radiation level detector. As a scintillation detector, when
radiation reaches the detector, light is emitted and measured. Scintillators have been used for many years for
radiation detection, however, conventional scintillators have used rigid crystals as the scintillation material.
The FiberFlexª utilizes a special fiber-optic bundle as the scintillator. This innovative approach brings significant
tangible advantages to the nuclear level gauge user over both solid scintillators and traditional ion chambers.
Application
Best suited for measurement of conductive liquids in regularly shaped conductive containers, capacitance level transmitters are also quite effective for measuring non-conductive materials (liquids and free flowing solids) and, through the use of an auxiliary probe, in irregular or non-conductive vessels.
The probe in the vessel must be continuously in contact with the medium to be measured. Erroneous level indications will be given if arching occurs or cavities form in the medium around the probe.
Specifications
| |
Rod probe CTR |
Light cable probe CTK |
Heavy duty cable probe CTN |
| wetted parts |
Insulated steel or SS316Ti |
| Ambient temperature |
-25°C to +85°C |
| Process temperature |
CT/CN: -25°C to +120°C;
CH/CL: -25°C to +200°C |
-25°C to +80°C |
| Process pressure |
max. 16 bar @ 200°C |
| Output |
4 to 20 mA |
| Capacitance ranges |
200 pF / 1 nF / 5 nF; selectable |
| ZERO adjustabiltiy |
0 to 80 % of measuring range |
| SPAN adjustability |
20 to 100% of measuring range |
| Measuring frequency |
25 kHz |
| Supply voltage |
12 to 30V DC, max 25 mA |
| Nonlinearity |
<0.5% |
| Protection |
IP65 |
| Ex certification |
EEx ia/ib IIB T4, TUV-A Nr.96.C.003X |
Download PDF data sheet (397kb)
|
NivoCap
Continuous Nuclear Level Detector
Features
- Two wire compact transmitter
- Rod probes up to 3 m
- Cable probes up to 20 m
- Fully or partly insulated probes
- Secondary lightning protection
- Various process connections
- Explosion proof models
Applications
- Liquids, powders, granules with relative dielectric constant e>2
- Chemicals with dense gas layers above the surface
- Viscous or corrosive materials
- High pressure, high temperature or vacuum
Specifications
| |
Power supply:
|
12-30VDC
|
| |
Temperature:
|
-25°C to +200°C
|
| |
Pressure:
|
max. 1.6 bar
|
| |
Output:
|
4-20 mA
|
| |
Process connection:
|
1" or 1 1/2" flanges
|
| |
Protection:
|
IP65
|
| |
Approvals:
|
EEx ia/ib IIB T4
|
|
|